PARAMETER:
ENGINE: DCEC 6B series diesel generator set, Rated power range is from 90kW to 120KW, 50Hz/60Hz, 1500 rpm/1800rpm
Engine model Rated power (50HZ) Rated power(60HZ)
6BT5.9-G1 92kw 100KW
6BT5.9-G2 90KW
6BTA5.9-G2 110KW 120KW
6BTAA5.9-G2 120KW 130KW
Alternator:
1. Variety: Customer can choose under different specification: Differ output power, single Phase or three Phase, two pole or four pole, single surpport or double support, for mainland or marine, and customer also can choose suitable transition connector or coupler.
2. Control system: Auto-voltage regulator have wet- proof, salt-proof, vibration-isolation fuctions.
3. Excition system: Any choosed permanent magnet alternator can solely supply electricity for excition system.
4. Insulation and proof: All alternator have H grade insulation and standard bad wether protection functions.
Highly integrated control system:
Three working model for choose: Stopage, automatic and hand startup model
Main fuction: Genset start, stopage fuction, displaying genset three Phase-voltage, current, engine water temperature, oil pressure, RPM and so on. And the governor is GAC governor.
Protection: When high water temperature, low oil pressure, over-speed, can automatically protect stopage, with the function of breakdown displaying.
Optional:
1. Sound-proof canopy.
2. Canopy with wheels.
3. Container type canopy.
Genset model Rated power Engine Alternator:
KC85GFW 85 KW 6BT5.9G MP-80-4(Marathon)
UCI274E(Stamford)
KC100GFW 33KW 6BTA5.9G MP-100-4(Marathon)
UCI274D(Stamford)
KC110GFW 110KW 6BTAA5.9-G2 MP-100-4(Marathon)
UCI274E(Stamford)
Generation Set |
Model |
KC20GFW |
KC30GFW |
KC45GFW |
KC75GFW |
KC90GFW |
KC100GFW |
KC145GFW |
KC200GFW |
|
Prime Power Rating Kw |
20 |
30 |
45 |
75 |
90 |
100 |
140 |
200 |
|
Standby Rating Kw |
22 |
33 |
50 |
80 |
100 |
110 |
150 |
200 |
|
Prime Power Rating Current (Amps) |
36 |
54 |
81 |
135 |
162 |
180 |
261 |
360 |
|
Maker |
NEW DIESEL MACHINERY CO.,LTD |
|
Dimension (L*W*H) |
1689*710*1150 |
1830*710*1150 |
2100*800*1450 |
2500*800*1500 |
2500*800*1500 |
2600*900*1500 |
2650*900*1600 |
2650*990*1600 |
|
Specific Fuel Consumption @ standby rating (Liter/hr) |
7.5 |
10.3 |
14.1 |
25 |
30 |
34 |
45 |
58 |
Engine |
Maker |
DCEC |
|
Model |
4B3.9-G2 |
4BT3.9-G2 |
4BTA3.9-G2 |
6BT5.9-G2 |
6BTA5.9-G2 |
6BTAA5.9-G2 |
6CTA8.3-G2 |
6LTAA8.9-G2 |
|
Standby/Prime power (kw) |
27/24 |
40/36 |
55/50 |
100/90 |
120/110 |
130/120 |
180/163 |
240/220 |
|
Cooling |
Water-Cooled |
|
Aspiration |
Natural |
Turbocharged and Aftercooled |
|
Aftercooling |
None |
None |
JW |
None |
JW |
CAC |
JW |
CAC |
|
No. of Cylinder |
4 |
4 |
4 |
6 |
6 |
6 |
6 |
6 |
|
RPM |
1500 |
|
Bore (mm) |
102 |
102 |
102 |
102 |
102 |
102 |
114 |
114 |
|
Stroke (mm) |
120 |
120 |
120 |
120 |
120 |
120 |
135 |
145 |
|
Displacement (Liter) |
3.9 |
3.9 |
3.9 |
5.9 |
5.9 |
5.9 |
8.3 |
8.9 |
|
Fuel |
0# |
|
Governor |
GAC electronic |
|
Starting System |
24V Electrical |
|
Lub Oil Specification |
15W40-CF |
|
Lub Oil Capacity (Liter) |
10.9 |
10.9 |
10.9 |
16.4 |
16.4 |
16.4 |
23.8 |
27.6 |
|
Coolant Capacity (Liter) |
8 |
8 |
8 |
9.9 |
9.9 |
9.9 |
12.3 |
11.1 |
|
Exhaust Pipe Size (mm) |
67 |
67 |
67 |
67 |
67 |
67 |
89 |
89 |
Alternator |
Maker (Brand) |
Newage (Stamford) |
|
Frame Size |
BCI184F |
BCI184J |
UCI224E |
UCI274C |
UCI274D |
UCI274E |
UCI274G |
UCDI274K |
|
Voltage |
380-415 V |
|
RPM/Frequency |
1500/50hz |
|
No. of Phase |
3 phase |
|
Power Factor |
0.8 (lag) |
|
Automatic Voltage Regulator |
SX460 (+/- 1.5%) |
AS440 (+/- 1.5%) |
|
Class of Insulation |
H |
Control Panel |
Make |
NDM |
|
Controller Brand/Type |
KC800 |
|
Breaker Rating (Amps) |
50 |
60 |
100A |
180 |
200 |
225 |
315 |
400A |
Fuel Tank |
Recom. capacity for running (hrs) |
8 |
Battery |
Rating (AH)--24V |
120AH |
165AH |
200AH |